DocumentCode :
1415320
Title :
Multi-area unit commitment for large-scale power systems
Author :
Tseng, C.-L. ; Guan, X. ; Svoboda, A.J.
Author_Institution :
Edison Enterprises, City of Industry, CA, USA
Volume :
145
Issue :
4
fYear :
1998
fDate :
7/1/1998 12:00:00 AM
Firstpage :
415
Lastpage :
421
Abstract :
A large-scale multi-area unit commitment is presented using a Lagrangian relaxation approach. The problem with a transmission network of several thousand buses and lines is equivalently modelled by a system with relatively few areas. Crucial tie-lines between areas are directly modelled. The network within an area is simplified from the application requirements. Based on a DC-flow model, the transmission constraints, as well as system demand and reserve requirements, are relaxed by attaching Lagrange multipliers to form a multiphase optimisation structure. A large-scale problem based on PG&E´s power system with more than 2200 buses and 2500 lines is tested. Small cases are also tested for comparison. The numerical testing results show that the method is able to handle transmission constraints in large-scale unit commitment problems
Keywords :
load dispatching; optimisation; power system interconnection; power transmission; scheduling; DC-flow model; Lagrange multipliers; Lagrangian relaxation; large-scale power systems; large-scale unit commitment; multi-area economic dispatch; multi-area unit commitment; multiphase optimisation structure; tie-lines; transmission constraints; transmission network;
fLanguage :
English
Journal_Title :
Generation, Transmission and Distribution, IEE Proceedings-
Publisher :
iet
ISSN :
1350-2360
Type :
jour
DOI :
10.1049/ip-gtd:19981987
Filename :
707088
Link To Document :
بازگشت