DocumentCode :
1415389
Title :
Simple computational model for calculating the unbalanced magnetic pull on a two-pole turbogenerator rotor due to eccentricity
Author :
Stoll, R.L.
Author_Institution :
Dept. of Electr. Eng., Southampton Univ., UK
Volume :
144
Issue :
4
fYear :
1997
fDate :
7/1/1997 12:00:00 AM
Firstpage :
263
Lastpage :
270
Abstract :
A model of a two-pole turbogenerator airgap region is developed in sufficient detail to predict the unbalanced magnetic pull on the rotor, under no-load conditions, caused by static eccentricity. The effects of rotor magnetic saturation and eddy currents are taken into account using a set of rotor surface impedances. The computer program is relatively simple and extremely fast in computation time on a modest PC
Keywords :
eddy currents; electric machine analysis computing; electromagnetic fields; machine theory; rotors; turbogenerators; computation time; computational model; computer simulation; eddy currents; personal computers; rotor magnetic saturation; rotor surface impedances; static eccentricity; two-pole turbogenerator rotor; unbalanced magnetic pull;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2352
Type :
jour
DOI :
10.1049/ip-epa:19971143
Filename :
612268
Link To Document :
بازگشت