DocumentCode :
1415723
Title :
An Ultrasonic Scanning Technique for In-Situ `Bowing´ Measurement of Prototype Fast Breeder Reactor Fuel Sub-Assembly
Author :
Swaminathan, K. ; Asokane, C. ; Sylvia, J.I. ; Kalyanasundaram, P. ; Swaminathan, P.
Author_Institution :
Fast Reactor Technol. Group, Indira Gandhi Centre for Atomic Res., Kalpakkam, India
Volume :
59
Issue :
1
fYear :
2012
Firstpage :
174
Lastpage :
181
Abstract :
An ultrasonic under-sodium scanner has been developed for deployment in Prototype Fast Breeder Reactor (PFBR) which is in advanced stage of construction at Kalpakkam, India. Its purpose is to scan the above-core plenum for detection, if any, of displacement of sub-assemblies. During its burn-up in the reactor, the head of a Fuel Sub-Assembly (FSA) may undergo a lateral shift from its original position (called `bowing´) due to the fast neutron induced damage on its structural material. A simple scanning technique has been developed for measuring the extent of bowing in-situ. This paper describes a PC-controlled mock-up of the scanner used to implement the scanning technique and the results obtained of scanning a mock-up FSA head under water. The details of the liquid-sodium proof transducer developed for use in the PFBR scanner and its performance are also discussed.
Keywords :
fission reactor fuel; fission reactor instrumentation; liquid metal fast breeder reactors; PC-controlled mock-up; PFBR scanner; fuel subassembly; in-situ bowing measurement; liquid-sodium proof transducer; prototype fast breeder reactor fuel sub-assembly; structural material; ultrasonic scanning technique; Acoustics; Crystals; Electron tubes; Head; Inductors; Transducers; FSA head; PC-control; in-situ bowing measurement; liquid sodium-proof transducer; ultrasonic scanning;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2011.2177476
Filename :
6123181
Link To Document :
بازگشت