Abstract :
Quantitative metabolic imaging in small animals with positron emission tomography (PET) requires the determination of the tracer concentration in whole blood, arterial plasma and metabolites as a function of time. A blood counting and sampling system was designed to simultaneously measure the time-activity curve as microvolumes of blood are collected. The system consists of a flow-through counter made of a plastic scintillator to detect positrons and of a computer-controlled blood sampler based on the concept of bubble segmentation. The number and size of samples, the withdrawal speed and the sampling time are programmable and can be modified on-line. Samples as small as 10 μl can be repetitively obtained from an implanted arterial catheter in the femoral vein or artery of small rats (150 g) or the jugular vein of mice (20 g). For medium sampling speed (100 μl/min) at a constant rate, the standard deviation of the sample activity is typically less than 1%. By cutting the tubing at the bubbles at the end of the experiment, samples are made available for further processing and biochemical analysis. This apparatus has become an essential tool for quantitative animal PET studies, allowing easy, reliable sampling at a low cost
Keywords :
biological techniques; blood; bubbles; computerised instrumentation; positron emission tomography; solid scintillation detectors; arterial plasma; biochemical analysis; biological research instrumentation; bubble segmentation; computer-controlled blood sampler; femoral vein; flow-through counter; implanted arterial catheter; jugular vein; metabolic PET studies; metabolites; mice; microvolumetric blood counter/sampler; nuclear biology; plastic scintillator; small animals; small rats; time-activity curve; tracer concentration determination; whole blood; Animals; Blood; Catheters; Counting circuits; Plasma measurements; Plastics; Positron emission tomography; Radiation detectors; Sampling methods; Veins;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.708343
Filename :
708343
Link To Document :
بازگشت