    Motion detection in triple scan SPECT imaging

  • Author

    Pellot-Barakat, C. ; Ivanovic, M. ; Weber, D.A. ; Herment, A. ; Shelton, D.K.

  • Author_Institution
    California Univ., Davis, CA, USA
  • Volume
    45
  • Issue
    4
  • fYear
    1998
  • fDate
    8/1/1998 12:00:00 AM
  • Firstpage
    2238
  • Lastpage
    2244
  • Abstract
    An algorithm to automatically detect and eliminate motion in projection data from triple scan SPECT imaging is proposed. The approach relies on a protocol where each head acquires projections over a full 360 degrees orbit rather than over the conventional 120 degrees partial orbit. Projection acquisition times are reduced to one third of that used for the partial orbit protocol to keep comparable total scan times. This protocol permits the acquisition of three full sets of SPECT data which can be adequately combined in order to reconstitute a motion-free set of projection data. Cross-correlation of the projection sets as a function of angle are used to detect motion. Plateaus of high correlation are estimated and matched in order to identify projections corresponding to the same position of a subject throughout a study. The motion correction algorithm was tested on experimental data obtained by manually moving a cardiac phantom at different times. In all cases, it was possible to reconstitute the evolution of the motion during the study. When no motion occurred during an interval equal to at least one third of the total acquisition time, high correlation plateaus were identified and complete sets of consistent projections were assembled from the longest matching plateaus. When more frequent motion occurred, an averaging of the three sets provided a means to improve the quality of the reconstructed slices compared to conventional imaging protocol
  • Keywords
    biomechanics; cardiology; image reconstruction; medical image processing; motion estimation; single photon emission computed tomography; cardiac phantom; cross-correlation; medical diagnostic imaging; motion correction algorithm; nuclear medicine; partial orbit protocol; patient motion detection; projection acquisition times reduction; reconstructed slices quality; triple scan SPECT imaging; Assembly; Detectors; Fractionation; Head; Image reconstruction; Imaging phantoms; Motion detection; Protocols; Testing; USA Councils;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.708357
  • Filename
    708357