DocumentCode :
1418274
Title :
Analysis of the ramp compensation approaches to improve stability for buck converters with constant on-time control
Author :
Qian, T. ; Wu, Wenchuan
Author_Institution :
Texas Instrum., Warwick, RI, USA
Volume :
5
Issue :
2
fYear :
2012
Firstpage :
196
Lastpage :
204
Abstract :
This study presents new sub-harmonic analysis for constant on-time control with ramp compensation. Ramp compensation of constant on-time control can be fulfilled by either directly feeding back a sensed inductor current signal as an internal ramp or using an external compensation ramp with a fixed slope during the off time and a fixed level during the on time. Based on the inductor current information and the charge variations of the output capacitor, the sub-harmonic mechanism is analysed in detail for constant on-time control with ramp compensation. Also, as well as explaining the benefits of using sensed inductor current signal, the effects of the sensed inductor current signal and the external compensation ramp are quantitatively compared. It is revealed that the external compensation ramp requires a lower ramp to avoid sub-harmonic oscillation. Based on the detailed theoretical analysis, experimental results demonstrate the stability criterion for constant on-time control with ramp compensation.
Keywords :
control engineering; electric current control; harmonic analysis; power convertors; buck converters; compensation ramp; constant on-time control; current mode control; inductor current signal; ramp compensation analysis; subharmonic analysis; subharmonic mechanism;
fLanguage :
English
Journal_Title :
Power Electronics, IET
Publisher :
iet
ISSN :
1755-4535
Type :
jour
DOI :
10.1049/iet-pel.2010.0374
Filename :
6126174
Link To Document :
بازگشت