DocumentCode :
1418759
Title :
Design and Implementation of a Portable Long-Term Physiological Signal Recorder
Author :
Vuorela, Timo ; Seppa, Ville-Pekka ; Vanhala, Jukka ; Hyttinen, Jari
Author_Institution :
Dept. of Electron., Tampere Univ. of Technol., Tampere, Finland
Volume :
14
Issue :
3
fYear :
2010
fDate :
5/1/2010 12:00:00 AM
Firstpage :
718
Lastpage :
725
Abstract :
This paper describes a design and implementation of a portable physiological signal recorder. The device is designed for measuring electrocardiography, bioimpedance, and user´s activity. The bioimpedance measures the dynamic changes in the impedance, and its main application is monitoring user´s respiration. Activity is measured with three-axis acceleration sensor. During the design, a special attention is paid on the device´s power consumption and the target has been set to a 24-h operating time. Functionality of the implemented measurement device is proven with test measurements, which include, e.g., comparison of measurement signals against reference signals, testing the device operation under vigorous upper body movements, and during a light exercise. In order to verify the device operation during real-life activities, one full day, 24-h long, measurement is carried out. The measurement system is tested with both commercial Ag/AgCl gel-paste electrodes and custom-made textile electrodes. Device is proven to be operational with both electrodes, but textile electrodes are found to be more sensitive for movement artifacts. This paper also gives a small review of other existing portable and wearable physiological measurement devices and discusses some general requirements of these devices.
Keywords :
bioelectric potentials; biomedical electrodes; electric impedance measurement; electrocardiography; patient monitoring; bioimpedance measurement; electrocardiography; gel-paste electrode; portable long term physiological signal recorder; power consumption; textile electrode; three axis acceleration sensor; time 24 h; user activity measurement; Bioimpedance; electrocardiography; long-term portable; physiological measurement; Artifacts; Clothing; Electric Impedance; Electrocardiography, Ambulatory; Electrodes; Equipment Design; Humans; Motor Activity; Signal Processing, Computer-Assisted; Textiles;
fLanguage :
English
Journal_Title :
Information Technology in Biomedicine, IEEE Transactions on
Publisher :
ieee
ISSN :
1089-7771
Type :
jour
DOI :
10.1109/TITB.2010.2042606
Filename :
5415564
Link To Document :
بازگشت