• DocumentCode
    1419820
  • Title

    Accurate (2 parts in 107) inductive voltage divider for 20-200 Hz

  • Author

    Deacon, T.A.

  • Author_Institution
    National Physical Laboratory, Teddington, UK
  • Volume
    117
  • Issue
    3
  • fYear
    1970
  • fDate
    3/1/1970 12:00:00 AM
  • Firstpage
    634
  • Lastpage
    640
  • Abstract
    The paper gives the design approach followed for, and the design details of, a 3-decade inductive voltage divider which will realise any 3-digit output/input ratio between 0.001:1 and 0.999:1 to an accuracy of within 2 parts in 107, or better, over the frequency range 20¿200Hz. The measurement technique used to establish the errors of the separate decades is described, and it is shown how these can be combined to give the overall error for any ratio setting. It is also shown how the overall output impedance of a multidecade divider can be calculated for any ratio setting from the knowledge of the resistance and leakage inductance per section of the separate decades. A method of compensating for the errors produced by internal admittance loading is also given.
  • Keywords
    calibration; potentiometers;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1970.0125
  • Filename
    5248990