Title :
Testing of elevator buffers by electrical means
Author_Institution :
Ohio State University, Columbus
Abstract :
The purpose of an elevator buffer is to stop the elevator in event it reaches the bottom of its hoistway out of control. To prevent injury to its occupants, the rate of stopping must not exceed 2 1/2 times gravity or about 80 feet per second per second for more than 1/25 second. The tests on a buffer should be such that the velocity at which the elevator strikes the buffer and the rate of deceleration at every point in the piston stroke may be determined. If the buffer contains oil, it is important for the designer to know also the oil pressure at every point in the stroke.
Keywords :
Carbon; Coils; Elevators; Harmonic analysis; Magnetic flux; Pistons; Pressure measurement;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1941.6432003