DocumentCode :
1420464
Title :
Method of measuring power-system frequencies
Author :
Nield, P.N.
Author_Institution :
University of Aston, Department of Electrical Engineering, Birmingham, UK
Volume :
117
Issue :
1
fYear :
1970
fDate :
1/1/1970 12:00:00 AM
Firstpage :
157
Lastpage :
160
Abstract :
A method of frequency measurement is described which uses a combination of digital and analogue techniques and is particularly suitable for measurements in the range 20¿500 Hz. An analysis is made of the errors inherent in the method. The design of a frequency meter covering the range 46¿51 Hz with a long-term accuracy within 0.05 Hz is given: a quartz crystal is used as a reference standard, and the frequency is displayed on a moving-coil meter. The design can readily be adapted for a different frequency range.
Keywords :
analogue computer methods; frequency measurement; power systems;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1970.0032
Filename :
5249095
Link To Document :
بازگشت