• DocumentCode
    1420972
  • Title

    Toward Simultaneous 2D ACAR and 2D DBAR: Sub-Pixel Spatial Characterization of a Segmented HPGe Detector Using Transient Charges

  • Author

    Williams, Christopher S. ; Baker, William P. ; Burggraf, Larry W. ; Adamson, Paul E. ; Petrosky, James C.

  • Author_Institution
    Air Force Inst. of Technol., Wright-Patterson AFB, OH, USA
  • Volume
    57
  • Issue
    2
  • fYear
    2010
  • fDate
    4/1/2010 12:00:00 AM
  • Firstpage
    860
  • Lastpage
    869
  • Abstract
    Sub-pixel spatial characterization of an Ortec HPGe double-sided strip detector was measured in preparation for its planned use in a positron annihilation spectrometer (PAS) to simultaneously measure the two-dimensional Angular Correlation (2D ACAR) and Doppler Broadening (2D DBAR) of Annihilation Radiation. Sr-85 514-keV photons were finely collimated onto the center of 25, equally spaced sub-pixels within a single 5-mm by 5-mm intrinsic pixel, using a collimator with an aperture diameter of 0.15 ?? 0.05 mm. The location of each full-energy recorded event was determined by analyzing the relative sizes of coincident transient charges on charge collection strips adjacent to the strip recording full-energy events. Interpolation, using ratios of the coincident transient charge sizes, was used to determine two-dimensional locations of full-energy events. Radial location data was fit to a function which describes a Gaussian point spread function uniformly distributed over a circular aperture. The standard deviation of the point spread function, 0.22 mm, is a measure of the spatial resolution of this detector system. The relative efficiency for detection of 514-keV photons across the intrinsic pixel was also measured.
  • Keywords
    germanium radiation detectors; image reconstruction; spectrometers; 2D ACAR; 2D DBAR; Gaussian point spread function; Ortec HPGe double-sided strip detector; PAS; charge collection strips adjacent; detector system; positron annihilation spectrometer; radial location data; segmented high performance Ge detector; subpixel spatial characterization; transient charges; two-dimensional Doppler broadening annihilation radiation; two-dimensional angular correlation annihilation radiation; Image charge; segmented germanium; spatial resolution; transient charge;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2010.2040194
  • Filename
    5416326