• DocumentCode
    1422419
  • Title

    Low-voltage coded excitation utilizing a miniaturized integrated ultrasound system employing piezoelectric 2-D arrays

  • Author

    Triger, Simon ; Saillant, Jean-Francois ; Démoré, Christine E M ; Cochran, Sandy ; Cumming, David R S

  • Author_Institution
    Dept. of Electron. & Electr. Eng., Univ. of Glasgow, Glasgow, UK
  • Volume
    57
  • Issue
    2
  • fYear
    2010
  • fDate
    2/1/2010 12:00:00 AM
  • Firstpage
    353
  • Lastpage
    362
  • Abstract
    We describe the development of an integrated, miniaturized ultrasound system designed for use with low-voltage piezoelectric transducer arrays. The technology targets low-frequency NDT and medium- to high-frequency sonar applications, at 1.2 MHz frequency. We have constructed a flexible, reconfigurable, low cost building block capable of 3-D beam forming. The tessellation of multiple building blocks permits formation of scalable 2-D macro-arrays of increased size and varying shape. This differs from conventional ultrasound solutions by integrating the entire system in a single module. No long RF cables are required to link the array elements to the electronics. The close coupling of the array and electronics assists in achieving adequate receive signal amplitudes with differential transmission voltages as low as ?? 3.3 V, although the system can be used at higher voltages. The system has been characterized by identifying flat-bottomed holes as small as 1 mm in diameter located at depths up to 190 mm in aluminum, and holes as small as 3 mm in diameter at a depth of 160 mm in cast iron. The results confirm the ability of the highly integrated system to obtain reflections from the targets despite the ?? 3.3 V excitation voltage by exploiting coding in low-voltage ultrasound.
  • Keywords
    array signal processing; encoding; monolithic integrated circuits; piezoelectric transducers; ultrasonic transducer arrays; 3D beam forming; frequency 1.2 MHz; high frequency sonar applications; low frequency NDT; low voltage coded excitation; low voltage piezoelectric transducer arrays; low voltage ultrasound coding; medium sonar applications; miniaturized integrated ultrasound system; piezoelectric 2D arrays; scalable 2D macroarrays; target reflections; Cables; Costs; Couplings; Piezoelectric transducers; Radio frequency; Shape; Sonar applications; Ultrasonic imaging; Ultrasonic transducer arrays; Voltage;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2010.1415
  • Filename
    5417194