The data acquisition and control system for the 4π detector CHIMERA
Author :
Aiello, S. ; Anzalone, A. ; Cardella, G. ; Cavallaro, S. ; Filippo, E. De ; Femino, S. ; Geraci, M. ; Giustolisi, F. ; Guazzoni, P. ; Jacono-Manno, C.M. ; Lanzalone, G. ; Lanzano, G. ; Nigro, S. Lo ; Pagano, A. ; Papa, M. ; Pirrone, S. ; Politi, G. ; Port
Author_Institution :
Ist. Nazionale di Fisica Nucl., Catania, Italy
Volume :
45
Issue :
4
fYear :
1998
fDate :
8/1/1998 12:00:00 AM
Firstpage :
1877
Lastpage :
1881
Abstract :
CHIMERA (Charged Heavy Ions Mass and Energy Resolving Array), a new 4π detector for charged particles is under development at various sites of the Istituto Nazionale di Fisica Nucleare. This paper describes the new data acquisition system built to handle the signals coming out from the detector with a rate up to 1 kHz on almost 5000 electronic channels. The required average throughput for the system is in the order of the 1 MB/s. The used converters allow double-range conversion on 15 bits, in less than 50 μs for all the 64 channels. The FDL link connects the different VME 9U crates performing a programmable hardware readout with a rate up to 100 MB/s. It uses a fast hardware protocol (Sparse Data Scan) to read the data buffers and send them to a FIC 8243 CPU board. A FIC 8243 dual-processor board forwards data (through Ethernet) to the analysis station (266 MHz Digital AlphaStation or Sun Sparcstation). A DLT (Digital Linear Tape) unit connected to analysis station is used to store data. The new data acquisition system has been tested under beam conditions at the Laboratorio Nazionale del Sud (Catania, Italy) and at GANIL (Caen, France)
Keywords :
data acquisition; digital signal processing chips; high energy physics instrumentation computing; nuclear electronics; physical instrumentation control; silicon radiation detectors; solid scintillation detectors; 1 MB/s; 1 kHz; 100 MB/s; 266 MHz; 4π detector; CHIMERA; Charged Heavy Ions Mass and Energy Resolving Array; Digital AlphaStation; Digital Linear Tape unit; FDL link; FIC 8243 CPU board; FIC 8243 dual-processor board; Sun Sparcstation; VME 9U crates; charged particles; control system; data acquisition; double-range conversion; fast hardware protocol; programmable hardware readout; sparse data scan; Control systems; Data acquisition; Detectors; Energy resolution; Hardware; Nuclear electronics; Protocols; Sensor arrays; Signal resolution; Throughput;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.710955
Filename :
710955
Link To Document :
بازگشت