Title :
Optimized acquisition time and image sampling for dynamic SPECT of Tl-201
Author :
Lau, Chi-Hoi ; Eberl, Stefan ; Feng, Dagan ; Lida, H. ; Lun, Pak-Kong ; Siu, Wan-chi ; Tamura, Yoshikazu ; Bautovich, George J. ; Ono, Yukihiko
Author_Institution :
Dept. of Comput. Sci., Sydney Univ., NSW, Australia
fDate :
6/1/1998 12:00:00 AM
Abstract :
With the recent development in scatter and attenuation correction algorithms, dynamic single photon emission computerized tomography (SPECT) can potentially yield physiological parameters, with tracers exhibiting suitable kinetics such as thallium-201 (Tl-201). A systematic way is proposed to investigate the minimum data acquisition times and sampling requirements for estimating physiological parameters with quantitative dynamic SPECT. Two different sampling schemes were investigated with Monte Carlo simulations: (1) Continuous data collection for total study duration ranging from 30-240 min. (2) Continuous data collection for first 10-45 min followed by a delayed study at approximately 3 h. Tissue time activity curves with realistic noise were generated from a mean plasma time activity curve and rate constants (K 1-k 4) derived from Tl-201 kinetic studies in 16 dogs. Full dynamic sampling schedules (DynSS) were compared to optimum sampling schedules (OSS). The authors found that OSS can reliably estimate the blood flow related K 1 and V d comparable to DynSS. A 30-min continuous collection was sufficient if only K 1 was of interest. A split session schedule of a 30-min dynamic followed by a static study at 3 h allowed reliable estimation of both K 1 and V d avoiding the need for a prolonged (>60-min) continuous dynamic acquisition. The methodology developed should also be applicable to optimizing sampling schedules for other SPECT tracers.
Keywords :
Monte Carlo methods; data acquisition; medical image processing; parameter estimation; single photon emission computed tomography; 10 to 240 min; Monte Carlo simulations; SPECT tracers; Tl; blood flow; diagnostic nuclear medicine; dogs; dynamic /sup 201/Tl SPECT; kinetic studies; mean plasma time activity curve; medical diagnostic imaging; rate constants; tissue time activity curves; Attenuation; Dynamic scheduling; Electromagnetic scattering; Heuristic algorithms; Image sampling; Kinetic theory; Particle scattering; Sampling methods; Scattering parameters; Single photon emission computed tomography; Animals; Dogs; Monte Carlo Method; Thallium Radioisotopes; Tomography, Emission-Computed, Single-Photon;
Journal_Title :
Medical Imaging, IEEE Transactions on