DocumentCode :
1425864
Title :
Nonrigid Motion Modeling of the Liver From 3-D Undersampled Self-Gated Golden-Radial Phase Encoded MRI
Author :
Buerger, C. ; Clough, R.E. ; King, A.P. ; Schaeffter, T. ; Prieto, C.
Author_Institution :
Div. of Imaging Sci. & Biomed. Eng., King´´s Coll. London, London, UK
Volume :
31
Issue :
3
fYear :
2012
fDate :
3/1/2012 12:00:00 AM
Firstpage :
805
Lastpage :
815
Abstract :
Magnetic resonance imaging (MRI) has been commonly used for guiding and planning image guided interventions since it provides excellent soft tissue visualization of anatomy and allows motion modeling to predict the position of target tissues during the procedure. However, MRI-based motion modeling remains challenging due to the difficulty of acquiring multiple motion-free 3-D respiratory phases with adequate contrast and spatial resolution. Here, we propose a novel retrospective respiratory gating scheme from a 3-D undersampled high-resolution MRI acquisition combined with fast and robust image registrations to model the nonrigid deformation of the liver. The acquisition takes advantage of the recently introduced golden-radial phase encoding (G-RPE) trajectory. G-RPE is self-gated, i.e., the respiratory signal can be derived from the acquired data itself, and allows retrospective reconstructions of multiple respiratory phases at any arbitrary respiratory position. Nonrigid motion modeling is applied to predict the liver deformation of an average breathing cycle. The proposed approach was validated on 10 healthy volunteers. Motion model accuracy was assessed using similarity-, surface-, and landmark-based validation methods, demonstrating precise model predictions with an overall target registration error of TRE = 1.70 ± 0.94 mm which is within the range of the acquired resolution.
Keywords :
biological tissues; biomedical MRI; deformation; image coding; image motion analysis; image reconstruction; image registration; image resolution; image sampling; liver; medical image processing; physiological models; pneumodynamics; 3D respiratory phases; 3D undersampled self-gated MRI; anatomy; breathing cycle; contrast; golden-radial phase encoding; image guided interventions; image reconstruction; image registration; landmark-based validation method; liver; magnetic resonance imaging; multiple respiratory phases; nonrigid deformation; nonrigid motion modeling; retrospective respiratory gating; similarity-based validation method; soft tissue visualization; spatial resolution; surface-based validation method; target registration error; Coils; Deformable models; Image reconstruction; Image resolution; Magnetic resonance imaging; Splines (mathematics); Three dimensional displays; Golden-radial phase encoding (G-RPE); liver; magnetic resonance imaging (MRI); motion modeling; nonrigid image registration; undersampling; Computer Simulation; Humans; Image Processing, Computer-Assisted; Liver; Magnetic Resonance Imaging; Reproducibility of Results; Respiratory-Gated Imaging Techniques;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2011.2181997