    Design and Validation of a Fully Implantable, Chronic, Closed-Loop Neuromodulation Device With Concurrent Sensing and Stimulation

  • Author

    Stanslaski, Scott ; Afshar, Pedram ; Cong, Peng ; Giftakis, Jon ; Stypulkowski, Paul ; Carlson, Dave ; Linde, Dave ; Ullestad, Dave ; Avestruz, Al-Thaddeus ; Denison, Timothy

  • Author_Institution
    Medtronic Neuromodulation, Minneapolis, MN, USA
  • Volume
    20
  • Issue
    4
  • fYear
    2012
  • fDate
    7/1/2012 12:00:00 AM
  • Firstpage
    410
  • Lastpage
    421
  • Abstract
    Chronically implantable, closed-loop neuromodulation devices with concurrent sensing and stimulation hold promise for better understanding the nervous system and improving therapies for neurological disease. Concurrent sensing and stimulation are needed to maximize usable neural data, minimize time delays for closed-loop actuation, and investigate the instantaneous response to stimulation. Current systems lack concurrent sensing and stimulation primarily because of stimulation interference to neural signals of interest. While careful design of high performance amplifiers has proved useful to reduce disturbances in the system, stimulation continues to contaminate neural sensing due to biological effects like tissue-electrode impedance mismatch and constraints on stimulation parameters needed to deliver therapy. In this work we describe systematic methods to mitigate the effect of stimulation through a combination of sensing hardware, stimulation parameter selection, and classification algorithms that counter residual stimulation disturbances. To validate these methods we implemented and tested a completely implantable system for over one year in a large animal model of epilepsy. The system proved capable of measuring and detecting seizure activity in the hippocampus both during and after stimulation. Furthermore, we demonstrate an embedded algorithm that actuates neural modulation in response to seizure detection during stimulation, validating the capability to detect bioelectrical markers in the presence of therapy and titrate it appropriately. The capability to detect neural states in the presence of stimulation and optimally titrate therapy is a key innovation required for generalizing closed-loop neural systems for multiple disease states.
  • Keywords
    biological tissues; biomedical electrodes; cellular biophysics; closed loop systems; diseases; medical disorders; neurophysiology; patient treatment; bioelectrical markers; biological effects; chronic; chronically implantable devices; closed-loop neural systems; closed-loop neuromodulation device; concurrent sensing; concurrent stimulation; counter residual stimulation disturbances; epilepsy; high performance amplifiers; large animal model; multiple disease states; nervous system; neural data; neural modulation; neural sensing; neural signals; neurological disease; optimally titrate therapy; patient therapy; seizure activity; seizure detection; stimulation parameter selection; stimulation parameters; systematic methods; tissue-electrode impedance mismatch; Classification algorithms; Closed loop systems; Electrical stimulation; Implantable biomedical devices; Medical treatment; Nervous system; Sensors; Chronic; closed-loop; neuromodulation; validation; Action Potentials; Animals; Biofeedback, Psychology; Brain; Deep Brain Stimulation; Electroencephalography; Equipment Design; Equipment Failure Analysis; Feedback; Monitoring, Ambulatory; Prostheses and Implants; Sheep; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2012.2183617
  • Filename
    6135801