Title :
Calibration of 2 cm spheres for gaps of less than 0.05 cm
Author :
Densley, R.J. ; Salvage, B.
Author_Institution :
National Research Council of Canada, Radio & Electrical Engineering Division, Ottawa, Canada
fDate :
5/1/1969 12:00:00 AM
Abstract :
Measurements of the breakdown voltages between 2cm-diameter brass, stainless-steel, and irradiated gold-plated stainless-steel spheres using direct, alternating and 1/50¿s impulse voltages with electrode gaps of up to 0.05cm are reported. In the absence of external irradiation, considerable scatter in the results was found, but, with irradiation, consistent behaviour was found.
Keywords :
electric breakdown; electric variables measurement; voltage measurement;
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
DOI :
10.1049/piee.1969.0167