• DocumentCode
    1427424
  • Title

    Contact bounce in dry reed relays

  • Author

    Jenkins, R.O.

  • Author_Institution
    M-O Valve Co. Ltd., Research Laboratories, Wembley, UK
  • Volume
    114
  • Issue
    11
  • fYear
    1967
  • fDate
    11/1/1967 12:00:00 AM
  • Firstpage
    1617
  • Lastpage
    1622
  • Abstract
    A simple theory is developed to account for contact bounce observed after closure of dry reed relays. The basic pattern of the bounce oscillograms is explained, and the theory also establishes the conditions under which bounce can occur. The effect of altering various operating parameters is discussed, and it is shown that in practice it is often difficult to reduce the bounce appreciably while maintaining other desirable operating characteristics. Some design modifications can, however, lead to a significant reduction of bounce.
  • Keywords
    electrical contacts; oscillations; relays;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1967.0310
  • Filename
    5250214