DocumentCode :
1427900
Title :
High-temperature (>500°c) wall thickness monitoring using dry-coupled ultrasonic waveguide transducers
Author :
Cegla, Frederic B. ; Cawley, Peter ; Allin, Jonathan ; Davies, Jacob
Author_Institution :
Dept. of Mech. Eng., Imperial Coll. London, London, UK
Volume :
58
Issue :
1
fYear :
2011
fDate :
1/1/2011 12:00:00 AM
Firstpage :
156
Lastpage :
167
Abstract :
Conventional ultrasonic transducers cannot withstand high temperatures for two main reasons: the piezoelectric elements within them depolarize, and differential thermal expansion of the different materials within a transducer causes them to fail. In this paper, the design of a high-temperature ultrasonic thickness gauge that bypasses these problems is described. The system uses a waveguide to isolate the vulnerable transducer and piezoelectric elements from the high-temperature measurement zone. Use of thin and long waveguides of rectangular cross section allows large temperature gradients to be sustained over short distances without the need for additional cooling equipment. The main problems that had to be addressed were the transmission and reception of ultrasonic waves into and from the testpiece that the waveguides are coupled to, and optimization of the wave propagation along the waveguide itself. It was found that anti-plane shear loading performs best at transmitting and receiving from the surface of a component that is to be inspected. Therefore, a nondispersive guided wave mode in large-aspect-ratio rectangular strips was employed to transmit the anti-plane shear loading from the transducer to the measurement zone. Different joining methods to attach the waveguides to the component were investigated and experiments showed that clamping the waveguides to the component surface gave the best results. The thickness of different plate samples was consistently measured to within less than 0.1 mm. Performance at high temperatures was tested in a furnace at 730°C for 4 weeks without signal degradation. Thicknesses in the range of 3 to 25 mm could be monitored using Hanning windowed tonebursts with 2 MHz center frequency.
Keywords :
condition monitoring; furnaces; gauges; high-temperature techniques; strips; thermal expansion; ultrasonic propagation; ultrasonic transducers; ultrasonic waves; Hanning windowed tonebursts; antiplane shear loading; differential thermal expansion; dry coupled ultrasonic waveguide transducers; high-temperature measurement zone; high-temperature ultrasonic thickness gauge; high-temperature wall thickness monitoring; large-aspect-ratio rectangular strips; nondispersive guided wave mode; piezoelectric elements; temperature 730 degC; ultrasonic waves; vulnerable transducer; wave propagation; Acoustics; Loading; Steel; Strips; Surface waves; Temperature measurement; Transducers;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2011.1782
Filename :
5688409
Link To Document :
بازگشت