• DocumentCode
    1428499
  • Title

    Determination of synchronous-machine parameters allowing for unequal mutual inductances

  • Author

    Takeda, Y. ; Adkins, B.

  • Author_Institution
    Imperial College of Science & Technology, Department of Electrical Engineering, London, UK
  • Volume
    121
  • Issue
    12
  • fYear
    1974
  • fDate
    12/1/1974 12:00:00 AM
  • Firstpage
    1501
  • Lastpage
    1504
  • Abstract
    The conventional theory of the synchronous machine is based on the assumption that the mutual inductances between the three direct-axis windings are all equal. The method is satisfactory for a calculation of the armature current, but the value of field current is considerably in error. Better results are obtained if another reactance is included in the equations to allow for additional coupling between the field and damper windings. The paper shows how the value of the additional reactance can be deduced from the short-circuit oscillograms.
  • Keywords
    inductance; machine theory; reactance; short-circuit currents; synchronous machines; additional reactance; determination of synchronous machine parameters; short circuit oscillograms; unequal mutual inductances;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1974.0313
  • Filename
    5250761