Title :
Determination of synchronous-machine parameters allowing for unequal mutual inductances
Author :
Takeda, Y. ; Adkins, B.
Author_Institution :
Imperial College of Science & Technology, Department of Electrical Engineering, London, UK
Volume :
121
Issue :
12
fYear :
1974
fDate :
12/1/1974 12:00:00 AM
Firstpage :
1501
Lastpage :
1504
Abstract :
The conventional theory of the synchronous machine is based on the assumption that the mutual inductances between the three direct-axis windings are all equal. The method is satisfactory for a calculation of the armature current, but the value of field current is considerably in error. Better results are obtained if another reactance is included in the equations to allow for additional coupling between the field and damper windings. The paper shows how the value of the additional reactance can be deduced from the short-circuit oscillograms.
Keywords :
inductance; machine theory; reactance; short-circuit currents; synchronous machines; additional reactance; determination of synchronous machine parameters; short circuit oscillograms; unequal mutual inductances;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1974.0313