DocumentCode
1428583
Title
SIGIF: a digital signal interchange format with application in neurophysiology
Author
Cunha, Manuel Bernardo ; Cunha, João Paulo Silva ; Silva, Tomás Oliveira e
Author_Institution
INESC, Aveiro, Portugal
Volume
44
Issue
5
fYear
1997
fDate
5/1/1997 12:00:00 AM
Firstpage
413
Lastpage
418
Abstract
Describes a biomedical digital-signal interchange format. The format supports both raw and processed data, multiple segments, several signal structures and representations, and an open architecture. Its versatility and adaptability allows the software to take advantage of any particular features of the acquisition hardware. The format has been used and improved in routine work during a five-year period involving the cooperation between two hospitals and one engineering research center. In order to support the format, an object oriented C language library has been developed and this is briefly described.
Keywords
bioelectric potentials; electronic data interchange; medical signal processing; neurophysiology; 5 y; SIGIF; acquisition hardware; clinical neurophysiology; digital signal interchange format; engineering research center; hospitals; multiple segments; object oriented C language library; open architecture; processed data; raw data; signal structures; Application software; Biology computing; Computer architecture; Digital signal processing; Digital systems; Hardware; Hospitals; Neurophysiology; Signal processing; Software libraries; Electrophysiology; Neurophysiology; Programming Languages; Signal Processing, Computer-Assisted; Software;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.568917
Filename
568917
Link To Document