DocumentCode
1430702
Title
New temperature test for synchronous machines
Author
Fong, W.
Author_Institution
University of Bristol, Department of Electrical Engineering, Bristol, UK
Volume
120
Issue
2
fYear
1973
fDate
2/1/1973 12:00:00 AM
Firstpage
241
Lastpage
242
Abstract
A novel temperature-test method for synchronous machines is described. The test machine is operated either as a motor at no load or as a generator supplying a reactive load, both with rated field excitation, while a second source is applied to cause full r.m.s. current to circulate in the armature winding. The test simulates a true temperature test in every respect, and is of special value for machines rated at power factors above 0.9. The new test may additionally be used to determine the machine efficiency at rated load.
Keywords
machine testing; synchronous machines; synchronous machines; temperature test method; thermal performance testing;
fLanguage
English
Journal_Title
Electrical Engineers, Proceedings of the Institution of
Publisher
iet
ISSN
0020-3270
Type
jour
DOI
10.1049/piee.1973.0050
Filename
5251160
Link To Document