• DocumentCode
    1430909
  • Title

    Three-Dimensional Imaging Properties of Rotation-Free Square and Hexagonal Micro-CT Systems

  • Author

    Quan, Enzhuo Michelle ; Lalush, David S.

  • Author_Institution
    Dept. of Biomed. Eng., North Carolina State Univ., Raleigh, NC, USA
  • Volume
    29
  • Issue
    3
  • fYear
    2010
  • fDate
    3/1/2010 12:00:00 AM
  • Firstpage
    916
  • Lastpage
    923
  • Abstract
    We study the 3-D imaging properties of a rotation-free micro-computed tomography (CT) system with square and hexagonal geometries. These systems use linear arrays of carbon-nanotube-based X-ray sources that are individually addressable. The source arrays and area detectors in the square and the hexagonal geometries form the sides of a polygon. The tomographic angular sampling for both geometries requires no motion of the sources, the detectors, or the subject. We demonstrate that the hexagonal geometry has improved angular coverage as compared to the square geometry. The ordered-subset convex iterative algorithm is implemented in both geometries for reconstructions from cone-beam projection data. Simulation studies show that both geometries can be effectively reconstructed with polychromatic or monochromatic source spectra. As a result of the incomplete tomographic sampling of the two geometries, some streaking artifacts appear in the reconstructed images. The hexagonal geometry, in general, produces fewer streaking artifacts than the square geometry. On the other hand, the two geometries perform quite similarly in resolution-noise trade-off, so we conclude that the proposed geometries are comparably effective for the rotation-free micro-CT and the hexagonal geometry is superior in reducing streaking artifacts.
  • Keywords
    carbon nanotubes; computerised tomography; image reconstruction; iterative methods; medical image processing; 3D imaging; X-ray computed tomography; carbon nanotube based X-ray sources; cone-beam projection data; image reconstruction; micro-computed tomography; monochromatic source spectra; ordered-subset convex iterative algorithm; polychromatic source spectra; streaking artifacts; tomographic angular sampling; Carbon nanotubes; Computed tomography; Detectors; Geometry; Image reconstruction; Motion detection; Optical imaging; Sampling methods; Sensor arrays; X-ray imaging; Carbon-nanotube; X-ray computed tomography; image reconstruction; micro-computed tomography (CT); Animals; Artifacts; Computer Simulation; Image Processing, Computer-Assisted; Imaging, Three-Dimensional; Mice; Nanotubes, Carbon; Phantoms, Imaging; Poisson Distribution; Whole Body Imaging; X-Ray Microtomography;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2009.2039799
  • Filename
    5423300