Title :
Thermal resistance between cable and duct
Author :
Buller, F. H. ; Neher, J. H.
Author_Institution :
General Electric Company, Schenectady, N. Y.
fDate :
5/1/1950 12:00:00 AM
Abstract :
ONE STEP in the calculation of underground cable temperatures involves the determination of the temperature rise of the cable surface above the immediately surrounding enclosure such as a duct structure or a gas- or oil-filled pipe. Since the intervening medium is a fluid, the mode of heat transfer simultaneously involves convection, conduction, and radiation.
Keywords :
Conductivity; Ducts; Oil filled cables; Optical fiber cables; Surface resistance; Thermal resistance;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1950.6433847