Title :
Artificial evaluation of the self-washing performance of contaminated insulators
Author_Institution :
UniversitÃ\xa0 di Napoli, Istituto Elettrotecnico, Facolta´´ di Ingegnena, Napoli, Italy
fDate :
9/1/1971 12:00:00 AM
Abstract :
Artificial-pollution tests are proposed in which the insulator self-washing characteristics are taken into account. The results obtained on different insulator types with high-and low-voltage tests suggest the introduction of convenient coefficients, with which information could be gained about the performance of polluted insulators under some typical conditions.
Keywords :
insulators; pollution; testing; evaluation; performance; polluted insulators; tests;
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
DOI :
10.1049/piee.1971.0240