    Numerical analysis of the electromagnetic flowmeter

  • Author

    Baker, Roger C.

  • Author_Institution
    Imperial College of Science & Technology, Department of Mechanical Engineering, London, UK
  • Volume
    120
  • Issue
    9
  • fYear
    1973
  • fDate
    9/1/1973 12:00:00 AM
  • Firstpage
    1039
  • Lastpage
    1043
  • Abstract
    The paper exploits the numerical solution of the flowmeter equation as an alternative to Bevir´s analytical method. The behaviour of flowmeters with point electrodes having short magnetic-field and insulating-liner lengths may be analysed for nonaxisymmetric rectlinear flow profiles. The numerical method can be more easily extended to situations which are complicated by flow profile, fluid properties and boundary conditions, but is less accurate than Bevir´s method because of the limitation of computer storage. The results obtained are compared with various exact solutions and are within about 1% of the exact values.
  • Keywords
    flowmeters; numerical methods; electromagnetic flowmeter; flowmeters; magnetohydrodynamics; numerical analysis;