DocumentCode :
1433493
Title :
Numerical analysis of the electromagnetic flowmeter
Author :
Baker, Roger C.
Author_Institution :
Imperial College of Science & Technology, Department of Mechanical Engineering, London, UK
Volume :
120
Issue :
9
fYear :
1973
fDate :
9/1/1973 12:00:00 AM
Firstpage :
1039
Lastpage :
1043
Abstract :
The paper exploits the numerical solution of the flowmeter equation as an alternative to Bevir´s analytical method. The behaviour of flowmeters with point electrodes having short magnetic-field and insulating-liner lengths may be analysed for nonaxisymmetric rectlinear flow profiles. The numerical method can be more easily extended to situations which are complicated by flow profile, fluid properties and boundary conditions, but is less accurate than Bevir´s method because of the limitation of computer storage. The results obtained are compared with various exact solutions and are within about 1% of the exact values.
Keywords :
flowmeters; numerical methods; electromagnetic flowmeter; flowmeters; magnetohydrodynamics; numerical analysis;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1973.0233
Filename :
5251657
Link To Document :
بازگشت