DocumentCode
1433493
Title
Numerical analysis of the electromagnetic flowmeter
Author
Baker, Roger C.
Author_Institution
Imperial College of Science & Technology, Department of Mechanical Engineering, London, UK
Volume
120
Issue
9
fYear
1973
fDate
9/1/1973 12:00:00 AM
Firstpage
1039
Lastpage
1043
Abstract
The paper exploits the numerical solution of the flowmeter equation as an alternative to Bevir´s analytical method. The behaviour of flowmeters with point electrodes having short magnetic-field and insulating-liner lengths may be analysed for nonaxisymmetric rectlinear flow profiles. The numerical method can be more easily extended to situations which are complicated by flow profile, fluid properties and boundary conditions, but is less accurate than Bevir´s method because of the limitation of computer storage. The results obtained are compared with various exact solutions and are within about 1% of the exact values.
Keywords
flowmeters; numerical methods; electromagnetic flowmeter; flowmeters; magnetohydrodynamics; numerical analysis;
fLanguage
English
Journal_Title
Electrical Engineers, Proceedings of the Institution of
Publisher
iet
ISSN
0020-3270
Type
jour
DOI
10.1049/piee.1973.0233
Filename
5251657
Link To Document