• DocumentCode
    1433659
  • Title

    Optimizing circular ring arrays for forward- looking IVUS imaging

  • Author

    Tekes, Coskun ; Karaman, M. ; Degertekin, F. Levent

  • Author_Institution
    Dept. of Electron. Eng., Isik Univ., Istanbul, Turkey
  • Volume
    58
  • Issue
    12
  • fYear
    2011
  • fDate
    12/1/2011 12:00:00 AM
  • Firstpage
    2596
  • Lastpage
    2607
  • Abstract
    Forward-looking (FL) catheter-based imaging systems are highly desirable for guiding interventions in intra- vascular ultrasound (IVUS) applications. One of the main challenges of array-based FL-IVUS systems is the large channel count, which results in increased system complexity. Synthetic phased-array processing with a reduced firing count simplifies the front-end and, hence, can enable 3-D real-time imaging. Recently, we have investigated dual-ring arrays suitable for IVUS imaging, in which the two concentric circular arrays are used separately as transmit (Tx) and receive (Rx) arrays. In this study, we present different optimized array designs based on dual and single circular rings which are suitable for synthetic phased-array processing with a reduced number of firings. To obtain an optimal firing set that produces low side lobes in the wideband response, we use a simulated annealing algorithm. In the simulations, we use 1.2-mm-diameter array configurations with 64 Tx and 58 Rx elements, a center frequency of 20 MHz and fractional bandwidths of 50% and 80%. The results show that optimized dual-ring arrays provide 8 dB improvements in peak near side-lobe level with no widening in the main lobe width when compared with full and other sparse co-arrays.
  • Keywords
    biomedical ultrasonics; blood vessels; catheters; diseases; medical image processing; simulated annealing; 3D real time imaging; catheter based imaging systems; circular ring arrays; dual ring array; forward looking IVUS imaging; intravascular ultrasound application; optimal firing; simulated annealing algorithm; synthetic phased array processing; wideband response; Apertures; Firing; Imaging; Kernel; Probes; Simulated annealing; Computer-Aided Design; Equipment Design; Equipment Failure Analysis; Image Enhancement; Transducers; Ultrasonography, Interventional;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2011.2123
  • Filename
    6141151