DocumentCode :
1436195
Title :
A.C./D.C. voltage-ratio box and 9-decade a.c. ratio standard
Author :
Deacon, T.A.
Author_Institution :
National Physical Laboratory, Teddington, UK
Volume :
118
Issue :
12
fYear :
1971
fDate :
12/1/1971 12:00:00 AM
Firstpage :
1853
Lastpage :
1858
Abstract :
The paper points out the limitations in trying to evaluate the d.c. performance of high-resistance d.c. voltage-ratio boxes directly from a series of a.c. measurements. It describes the design approach and gives design details of a guarded resistive a.c./d.c. voltage-ratio box (v.r.b.) the a.c. performance of which, in the band 20 Hz¿80 Hz, is such as to produce an uncertainty of less than 1 part in 106 in extrapolating to 0 Hz (d.c.) This v.r.b. can then be used as a standard in direct d.c. calibration of other v.r.b.s. Design criteria and details are also given of the 9-decade low-frequency inductive voltage divider (i.v.d.) which serves as the standard in the a.c. measurements. Also described is a 1000 V 50 Hz single decade i.v.d. designed to precede the 9-decade i.v.d. in evaluating the self-heating effects when the v.r.b. is operated at rated voltage on its higher voltage ranges.
Keywords :
measurement standards; resistance measurement; 20 to 80 Hz; frequency measurement; inductive voltage divider; measurement standards; resistance measurement; voltage measurement; voltage ratio box;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1971.0349
Filename :
5252091
Link To Document :
بازگشت