• DocumentCode
    1438741
  • Title

    A proposed method for the determination of current-transformer errors

  • Author

    Camilli, G. ; Broeck, R. L. Ten

  • Author_Institution
    General Electric Company, Pittsfield, Mass.
  • Volume
    59
  • Issue
    9
  • fYear
    1940
  • Firstpage
    547
  • Lastpage
    550
  • Abstract
    CURRENT TRANSFORMERS for relay service must be able to function with reasonable accuracy under very high overload conditions, and it is therefore necessary that their accuracy for such high currents be verified. However, in performing the usual accuracy test at very high currents, certain difficulties are encountered — the principal ones being:
  • Keywords
    Current transformers; Phase transformers; Power transformers; Transformer cores; Voltage measurement; Windings;