• DocumentCode
    1438870
  • Title

    Public-supply-system distortion and unbalance from single-phase a.c. traction

  • Author

    Howroyd, D.C.

  • Author_Institution
    Central Electricity Generating Board, Planning Department, System Technical Branch, London, UK
  • Volume
    124
  • Issue
    10
  • fYear
    1977
  • fDate
    10/1/1977 12:00:00 AM
  • Firstpage
    853
  • Lastpage
    859
  • Abstract
    A.C. traction loads cause the public supply voltage to be unbalanced on the three phases and distorted in waveform. These effects are potentially harmful, and it is necessary to understand and limit them in the interests of other parties. For this purpose, a method of prediction has been devised using the well known harmonic and phase-sequence components to make the calculation practicable. Although the manipulation of these components for single-phase traction supplies is complicated, prone to error and full of pitfalls, a simple method of calculation is illustrated.
  • Keywords
    electric distortion; harmonic analysis; load (electric); load regulation; power systems; traction; public supply system distortion; single phase AC traction loads; waveform distortion;