• DocumentCode
    1439169
  • Title

    Transactions: Transient starting torques in induction motors

  • Author

    Wahl, A. M. ; Kilgore, L. A.

  • Author_Institution
    Westinghouse Electric and Manufacturing Company, East Pittsburgh, Pa.
  • Volume
    59
  • Issue
    11
  • fYear
    1940
  • Firstpage
    603
  • Lastpage
    607
  • Abstract
    A transient fundamental-frequency torque is shown to occur in the starting of all induction motors. For full-voltage starting on a general-purpose squirrel-cage motor, this torque may be as high as two or three times the pull-out torque. A consideration of such torques is particularly advisable for cases where induction motors are started and stopped frequently or continuously, since under such conditions mechanical failure of the motor or associated parts, gearing, couplings, etc., may occur if the stresses exceed the endurance limit of the material.
  • Keywords
    Equations; Induction motors; Mathematical model; Rotors; Shafts; Torque; Transient analysis;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1940.6435175
  • Filename
    6435175