Abstract :
A transient fundamental-frequency torque is shown to occur in the starting of all induction motors. For full-voltage starting on a general-purpose squirrel-cage motor, this torque may be as high as two or three times the pull-out torque. A consideration of such torques is particularly advisable for cases where induction motors are started and stopped frequently or continuously, since under such conditions mechanical failure of the motor or associated parts, gearing, couplings, etc., may occur if the stresses exceed the endurance limit of the material.
Keywords :
Equations; Induction motors; Mathematical model; Rotors; Shafts; Torque; Transient analysis;