DocumentCode
1439169
Title
Transactions: Transient starting torques in induction motors
Author
Wahl, A. M. ; Kilgore, L. A.
Author_Institution
Westinghouse Electric and Manufacturing Company, East Pittsburgh, Pa.
Volume
59
Issue
11
fYear
1940
Firstpage
603
Lastpage
607
Abstract
A transient fundamental-frequency torque is shown to occur in the starting of all induction motors. For full-voltage starting on a general-purpose squirrel-cage motor, this torque may be as high as two or three times the pull-out torque. A consideration of such torques is particularly advisable for cases where induction motors are started and stopped frequently or continuously, since under such conditions mechanical failure of the motor or associated parts, gearing, couplings, etc., may occur if the stresses exceed the endurance limit of the material.
Keywords
Equations; Induction motors; Mathematical model; Rotors; Shafts; Torque; Transient analysis;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1940.6435175
Filename
6435175
Link To Document