Title :
An improved type of D-C wattmeter of the shunted type
Author_Institution :
Westinghouse Electric and Manufacturing Company, Newark, N. J.
Abstract :
While wattmeters for high current values of a-c power are universally used in connection with instrument transformers, d-c power is ordinarily measured by using separate ammeters and voltmeters on account of the difficulty in making a heavy-current d-c wattmeter. Although large direct currents are conveniently measured by use of the shunt and milli-voltmeter, shunted-type d-c wattmeters have in the past been somewhat unsatisfactory. An improved d-c wattmeter is described which corresponds in accuracy and sensitivity to the usual permanent-magnet moving-coil ammeter and operates from the usual ammeter shunt.
Keywords :
Ammeters; Coils; Electromagnets; Magnetic cores; Resistance; Wattmeters;
Journal_Title :
Electrical Engineering
DOI :