• DocumentCode
    1441067
  • Title

    Interlaboratory comparison of radiated emission measurements using a spherical dipole radiator

  • Author

    Kang, T.-W. ; Chung, Y.C. ; Won, S.-H. ; Kim, H.-T.

  • Author_Institution
    Electromagn. Comput. Group, Korea Res. Inst. of Stand. & Sci., Taejon, South Korea
  • Volume
    148
  • Issue
    1
  • fYear
    2001
  • fDate
    1/1/2001 12:00:00 AM
  • Firstpage
    35
  • Lastpage
    40
  • Abstract
    An interlaboratory radiated emission comparison has been performed, comparing electric field strength measurements in the frequency range 30-1000 MHz at a 10 m open area test site. A spherical dipole radiator is employed as a reference emitter. Comparison results are presented in terms of measurement repeatability of electric field strengths measured at test sites for each frequency. Expanded uncertainty for the 95.45% confidence level is evaluated to be +5.6/-5.7 dB and +4.9/-4.8 dB for the frequency ranges corresponding to biconical and log-periodic antennas, respectively. Uncertainty analysis demonstrates that the uncertainty mainly stems from the antenna factor calibration, mismatch, the performance of a receiver and site imperfection
  • Keywords
    dipole antennas; electric field measurement; electromagnetic compatibility; log periodic antennas; measurement standards; measurement uncertainty; 10 m; 10 m open area test site; 30 to 1000 MHz; antenna factor calibration; biconical antennas; electric field strength; electric field strength measurement; frequency range 30-1000 MHz; log-periodic antenna; mismatch; radiated emission measurement; reference emitter; repeatability; site imperfection; spherical dipole radiator; uncertainty; uncertainty analysis;
  • fLanguage
    English
  • Journal_Title
    Science, Measurement and Technology, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2344
  • Type

    jour

  • DOI
    10.1049/ip-smt:20010184
  • Filename
    903472