• DocumentCode
    1441576
  • Title

    Proton-induced changes in CTE for n-channel CCDs and the effect on star tracker performance

  • Author

    Hopkinson, Gordon R.

  • Author_Institution
    Sira Electro-Opt. Ltd., Chislehurst, UK
  • Volume
    47
  • Issue
    6
  • fYear
    2000
  • fDate
    12/1/2000 12:00:00 AM
  • Firstpage
    2460
  • Lastpage
    2465
  • Abstract
    Proton-induced changes in charge transfer efficiency of two CCD types with differing pixel sizes have been characterized in detail and compared with measurements of the shift in position of artificial star images to determine the impact on star tracker performance. Errors in star position are large at low backgrounds but can be limited to less than 0.1 pixels for 10 krd(Si) proton environments (e.g., 15 years GEO) if the background is high and windowed readout is used
  • Keywords
    CCD image sensors; optical tracking; proton effects; space vehicle electronics; 10 krad; CTE; GEO; artificial star images; charge transfer efficiency; n-channel CCDs; pixel sizes; proton-induced changes; star position errors; star tracker performance; windowed readout; Charge coupled devices; Charge measurement; Charge transfer; Current measurement; Image storage; Pixel; Position measurement; Protons; Size measurement; Temperature sensors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.903793
  • Filename
    903793