• DocumentCode
    1442612
  • Title

    Photographic investigation of breakdown of composite insulation

  • Author

    Auckland, D.W. ; Borishade, A.B. ; Cooper, R.

  • Author_Institution
    University of Manchester, Electrical Engineering Laboratories, Manchester, UK
  • Volume
    124
  • Issue
    12
  • fYear
    1977
  • fDate
    12/1/1977 12:00:00 AM
  • Firstpage
    1263
  • Lastpage
    1266
  • Abstract
    The alternating and impulse-voltage breakdown of a composite consisting of a column of air in series with a solid dielectric layer has been investigated. Breakdown is initiated in the solid some 60 ns before voltage collapse, and not by the establishment of a plasma throughout the air column, as supposed by a current hypothesis. This is also true for a liquid/solid composite.
  • Keywords
    electric breakdown of solids; insulation testing; photographic applications; AC voltage; composite insulation; electric breakdown; impulse voltage; solid dielectric layer;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1977.0266
  • Filename