DocumentCode :
1443103
Title :
Calculation of capacitance of adjacent steps in parallel-plane transmission lines
Author :
Griffin, E.J. ; Harris, I.A.
Author_Institution :
Royal Signals and Radar Establishment, Malvern, UK
Volume :
123
Issue :
8
fYear :
1976
fDate :
8/1/1976 12:00:00 AM
Firstpage :
729
Lastpage :
733
Abstract :
Explicit solutions are presented for the capacitance arising from the electric field distortion caused by one of two step discontinuities bounding a short length of increased or decreased conductor spacing in parallel-plane transmission lines. Values are tabulated of a proximity factor which may be multiplied by the capacitance resulting from the field distortion associated with an isolated step to account for the presence of a second, similar step.
Keywords :
capacitance; power transmission lines; capacitance; conductor spacing; electric field distortion; isolated step; parallel plane transmission line; proximity factor; step discontinuities;