DocumentCode :
1443240
Title :
The registration of harmonic power by analog and digital power meters
Author :
Driesen, Johan ; Van Craenenbroeck, Thierry ; Van Dommelen, Daniel
Author_Institution :
Dept. of Electr. Eng., Katholieke Univ., Leuven, Heverlee, Belgium
Volume :
47
Issue :
1
fYear :
1998
fDate :
2/1/1998 12:00:00 AM
Firstpage :
195
Lastpage :
198
Abstract :
This paper discusses the measurement error of energy meters operating under harmonic distortion. A system to determine the magnitude of the error caused by an individual harmonic is used to generate curves on which the error introduced by different frequency components is displayed. An algorithm using these data to predict the resulting measurement error of a linearly operating energy meter registering under circumstances of any known harmonics in the voltage and the current is presented
Keywords :
digital instrumentation; electric distortion measurement; harmonic analysis; harmonic distortion; measurement errors; power measurement; power system measurement; reactive power; analog power meters; digital power meters; energy meters; frequency components; harmonic distortion; harmonic power; measurement error; reactive energy; Energy measurement; Harmonic distortion; Measurement errors; Power measurement; Power quality; Power system harmonics; Reactive power; Testing; Voltage; Watthour meters;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.728817
Filename :
728817
Link To Document :