• DocumentCode
    1444323
  • Title

    Experimental evaluation of using the surge PD test as a predictive maintenance tool for monitoring turn insulation quality in random wound AC motor stator windings

  • Author

    Yang, Jinkyu ; Kang, Tae-june ; Kim, Byunghwan ; Lee, Sang Bin ; Yoon, Young-Woo ; Kang, Dongsik ; Cho, Jintae ; Kim, Heedong

  • Author_Institution
    Dept. of Electr. Eng., Korea Univ., Seoul, South Korea
  • Volume
    19
  • Issue
    1
  • fYear
    2012
  • fDate
    2/1/2012 12:00:00 AM
  • Firstpage
    53
  • Lastpage
    60
  • Abstract
    Turn insulation degradation is one of the major root causes of stator insulation failure leading to motor breakdown. The surge test is the only test available for testing the integrity of turn insulation; however, it is a high voltage pass/fail test that provides an indication only if an arc is instigated between the turns of weakened turn insulation, and therefore does not provide information regarding remaining lifetime. The surge PD test measures the partial discharge (PD) activity under surge excitation, and is used to date for assuring that voltage source PWM inverter-fed motors (IEC 60034-18-41 type I) are PDfree. In this paper, the potential of using the surge PD test as a predictive maintenance tool for turn insulation quality assessment is evaluated. Under the expectation that increasing PD activity in the voids formed by insulation degradation may be detectable before turn insulation failure, the test is performed periodically under accelerated thermal degradation on 6 windings. It is shown that change in the PD inception voltage under the surge PD test can be clearly observed before any other insulation test indicator. The results suggest that the surge PD test can be used for monitoring the condition of turn insulation for providing an early indication of stator insulation problems without the risk of puncturing turn insulation.
  • Keywords
    AC motor protection; condition monitoring; failure (mechanical); insulation testing; partial discharges; stators; surge protection; PD inception voltage; accelerated thermal degradation; condition monitoring; high voltage pass-fail test; insulation degradation; motor breakdown; partial discharge activity; predictive maintenance tool; puncturing turn insulation failure; random wound AC motor stator winding; stator insulation failure; stator insulation problem indication; surge PD test; surge excitation; turn insulation quality monitoring; voltage source PWM inverter-fed motor; weakened turn insulation test indicator; Degradation; Insulation; Partial discharges; Stator windings; Surges; Temperature measurement; Voltage measurement; AC machines; impulse testing; monitoring; partial discharges (PD); rotating machine insulation test; surges;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2012.6148502
  • Filename
    6148502