• DocumentCode
    1444337
  • Title

    Temperature limits and measurements for rating of D-C machines

  • Author

    Compton, F. A.

  • Author_Institution
    General Electric Company, Erie, Pa.
  • Volume
    62
  • Issue
    12
  • fYear
    1943
  • Firstpage
    780
  • Lastpage
    785
  • Abstract
    Existing industrial practice for determining the temperature rise of d-c machines is based on measurements with thermometers, placed on exposed or accessible surfaces of the machine. Tests using resistance measurements with improvements in technique have disclosed the existence of considerably higher internal temperatures than those indicated by thermometers, especially for short-time rated machines. Experience has indicated, nevertheless, that such machines have entirely satisfactory service records. Greater accuracy and consistency are possible with the resistance method, with proper measurement techniques, and it affords a truer indication of winding temperatures. This paper, therefore, suggests that the resistance method should be more generally used and should ultimately be recognized in the Standards as is now the case for railway motors. With this in view, detailed recommendations for resistance-measurement technique are presented. Correlation of the temperature rises determined by the resistance method with those measured by the thermometer method is necessary if resistance methods are to supplant the now standard thermometer methods. This paper shows the relation existing between temperature rises measured by thermometer and those measured by resistance on variously ventilated and insulated machines. Values for temperature limits measured by resistance for continuous and short-time rated class-A and class-B insulated d-c machines are presented. These are consistent with the recently published AIEE Standard 1A “Report on General Principles for Rating of Electrical Apparatus for Short-time, Intermittent or Varying Duty.” The information presented in this paper is intended to apply primarily to low-voltage (approximately 600 volts maximum) d-c machines with form-wound armature coils and conventional types of field coils.
  • Keywords
    Electrical resistance measurement; Insulation; Resistance; Resistance heating; Standards; Temperature measurement; Windings;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1943.6436045
  • Filename
    6436045