• DocumentCode
    1444605
  • Title

    Thyristor chopper control and the introduction of harmonic currents into track circuits. Practical tests

  • Author

    Duck, E.W. ; Lawrence, L.S. ; Lowe, T.J.

  • Author_Institution
    London Transport, Acton Works, London, UK
  • Volume
    123
  • Issue
    6
  • fYear
    1976
  • fDate
    6/1/1976 12:00:00 AM
  • Firstpage
    523
  • Lastpage
    530
  • Abstract
    The paper covers the practical measurements made, by London Transport, on the levels of induced current in track circuits produced by conventional and thyristor-(chopper-) type traction equipment on their 4th-rail traction supply system. The method of measurement, the subsequent method of analysis and the implications of the results are described and discussed.
  • Keywords
    choppers (circuits); electric current measurement; harmonic analysis; thyristor applications; traction; harmonic currents; induced current; measurements; practical tests; thyristor chopper control; track circuits; traction supply system;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1976.0119
  • Filename
    5253751