DocumentCode
1445383
Title
Effect of corona on the density of ionisation in a highߝvoltage laboratory
Author
Allen, N.L. ; Allibone, T.E. ; Dring, D.
Author_Institution
Leeds University, Department of Electrical & Electronic Engineering, Leeds, UK
Volume
124
Issue
2
fYear
1977
fDate
2/1/1977 12:00:00 AM
Firstpage
174
Lastpage
178
Abstract
Ion densities in a closed laboratory due to d.c. corona from an impulse-voltage generator and its charging set have been measured by means of a Gerdien-type aspirator. By comparison with natural ionisation, the densities of ions of the same polarity as the generator charging voltage were increased by two orders of magnitude, but ions of opposite sign were greatly reduced in density. Use of a filtering aspirator yielded information on the densities of ´large´ ions which were shown to be an important part of the total ionisation occurring under natural and corona conditions. The significance of the results for impulse-voltage testing is briefly discussed.
Keywords
corona; high-voltage techniques; impulse testing; ionisation of gases; laboratory apparatus and techniques; pulse generators; corona; high voltage laboratory; impulse voltage generator; impulse voltage testing; ionisation;