DocumentCode
1445606
Title
Design and Development of Separation Septa for the CERN PS Booster Upgrade
Author
Balhan, B. ; Borburgh, J. ; Hourican, M. ; Masson, T.
Author_Institution
TE Dept., CERN, Geneva, Switzerland
Volume
22
Issue
3
fYear
2012
fDate
6/1/2012 12:00:00 AM
Firstpage
4000304
Lastpage
4000304
Abstract
The CERN PS Booster project foresees the injection of 160 MeV H- ions into the booster from Linac 4. For this substantial upgrade, a system of 5 pulsed magnets (BIDIS) and 3 vertical septa (BISMV) will distribute the Linac pulses into the four-vertically separated Booster injection lines before being injected into the rings. This paper describes the magnetic calculations and the design concept that will be used in the future upgrade of the BISMV. Subsequently the mechanical design of the septa and their integration into the existing transfer line will be discussed.
Keywords
linear accelerators; superconducting magnets; BIDIS; BISMV; CERN PS booster upgrade; Linac 4; booster injection lines; electron volt energy 160 MeV; magnetic calculations; mechanical design; separation septa; vertical deflecting septa; Magnetic circuits; Magnetic flux; Magnetic separation; Magnetomechanical effects; Magnetosphere; Saturation magnetization; Steel; Vacuum tank; vertical deflecting septa;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2012.2187511
Filename
6151055
Link To Document