• DocumentCode
    1446169
  • Title

    Prognosis of Right Ventricular Failure in Patients With Left Ventricular Assist Device Based on Decision Tree With SMOTE

  • Author

    Wang, Yajuan ; Simon, Marc ; Bonde, Pramod ; Harris, Bronwyn U. ; Teuteberg, Jeffrey J. ; Kormos, Robert L. ; Antaki, James F.

  • Author_Institution
    Dept. of Biomed. Eng., Carnegie Mellon Univ., Pittsburgh, PA, USA
  • Volume
    16
  • Issue
    3
  • fYear
    2012
  • fDate
    5/1/2012 12:00:00 AM
  • Firstpage
    383
  • Lastpage
    390
  • Abstract
    Right ventricular failure is a significant complication following implantation of a left ventricular assist device (LVAD), which increases morbidity and mortality. Consequently, researchers have sought predictors that may identify patients at risk. However, they have lacked sensitivity and/or specificity. This study investigated the use of a decision tree technology to explore the preoperative data space for combinatorial relationships that may be more accurate and precise. We retrospectively analyzed the records of 183 patients with initial LVAD implantation at the Artificial Heart Program, University of Pittsburgh Medical Center, between May 1996 and October 2009. Among those patients, 27 later required a right ventricular assist device (RVAD+) and 156 remained on LVAD (RVAD-) until the time of transplantation or death. A synthetic minority oversampling technique (SMOTE) was applied to the RVAD+ group to compensate for the disparity of sample size. Twenty-one resampling levels were evaluated, with decision tree model built for each. Among these models, the top six predictors of the need for an RVAD were transpulmonary gradient (TPG), age, international normalized ratio (INR), heart rate (HR), aspartate aminotransferase (AST), prothrombin time, and right ventricular systolic pressure. TPG was identified to be the most predictive variable in 15 out of 21 models, and constituted the first splitting node with 7 mmHg as the breakpoint. Oversampling was shown to improve the senstivity of the models monotonically, although asymptotically, while the specificity was diminished to a lesser degree. The model built upon 5X synthetic RVAD+ oversampling was found to provide the best compromise between sensitivity and specificity, included TPG (layer 1), age (layer 2), right atrial pressure (layer 3), HR (layer 4,7), INR (layer 4, 9), alanine aminotransferase (layer 5), white blood cell count (layer 5,6, &7), the number of inotrope agents (layer 6), creatinine (layer 8), A- T (layer 9, 10), and cardiac output (layer 9). It exhibited 85% sensitivity, 83% specificity, and 0.87 area under the receiver operating characteristic curve (RoC), which was found to be greatly improved compared to previously published studies.
  • Keywords
    biological organs; biomechanics; biomedical equipment; cardiovascular system; decision trees; diseases; failure (mechanical); physiological models; sensitivity analysis; University of Pittsburgh Medical Center; alanine aminotransferase; artificial heart program; aspartate aminotransferase; cardiac output; creatinine; decision tree technology; heart rate; international normalized ratio; left ventricular assist device; morbidity; mortality; preoperative data space; pressure 7 mm Hg; prothrombin time; receiver operating characteristic curve; right atrial pressure; right ventricular failure prognosis; splitting node; synthetic minority oversampling technique; transpulmonary gradient; white blood cell count; Decision trees; Educational institutions; Heart rate; Mercury (metals); Predictive models; Sensitivity; Heart failure; modeling (decision tree); right ventricular assist device (RVAD); synthetic minority oversampling technique (SMOTE); Decision Trees; Heart Failure; Heart-Assist Devices; Humans; Models, Statistical; Prognosis; Retrospective Studies; Ventricular Dysfunction, Left; Ventricular Dysfunction, Right;
  • fLanguage
    English
  • Journal_Title
    Information Technology in Biomedicine, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1089-7771
  • Type

    jour

  • DOI
    10.1109/TITB.2012.2187458
  • Filename
    6151155