DocumentCode
1453023
Title
Tensorial study of six phase delta-fork connected mercury arc rectifier
Author
Muthupadhyan, Asok Kumar
Volume
12
Issue
2
fYear
1974
Firstpage
45
Lastpage
54
Abstract
Kron´s tensorial approach has been followed in the analysis to study the six phase delta-fork connected Mercury Arc Rectifier Circuit. The connection matrix of the rectifier transformer has been developed starting from the coil current and neglecting the magnetizing current with due consideration of firing order of anodes. The impedance tensor and voltage matrices are also developed and r.m.s. leakage impedance drop is calculated and study has then been extended to determine the performance characteristics of the rectifier. The theoretical results are verified experimentally.
Keywords
mercury arc rectifiers; Kron´s tensorial method; anode firing order; coil current; connection matrix; delta fork connected rectifier; experimental results; impedance tensor; mercury arc rectifier; performance characteristics; r.m.s. leakage impedance drop; rectifier transformer; six phase rectifier; tensorial study; theoretical results; voltage matrices;
fLanguage
English
Journal_Title
India, IEE-IERE Proceedings -
Publisher
iet
ISSN
0018-9146
Type
jour
DOI
10.1049/iipi.1974.0014
Filename
5257670
Link To Document