• DocumentCode
    1453023
  • Title

    Tensorial study of six phase delta-fork connected mercury arc rectifier

  • Author

    Muthupadhyan, Asok Kumar

  • Volume
    12
  • Issue
    2
  • fYear
    1974
  • Firstpage
    45
  • Lastpage
    54
  • Abstract
    Kron´s tensorial approach has been followed in the analysis to study the six phase delta-fork connected Mercury Arc Rectifier Circuit. The connection matrix of the rectifier transformer has been developed starting from the coil current and neglecting the magnetizing current with due consideration of firing order of anodes. The impedance tensor and voltage matrices are also developed and r.m.s. leakage impedance drop is calculated and study has then been extended to determine the performance characteristics of the rectifier. The theoretical results are verified experimentally.
  • Keywords
    mercury arc rectifiers; Kron´s tensorial method; anode firing order; coil current; connection matrix; delta fork connected rectifier; experimental results; impedance tensor; mercury arc rectifier; performance characteristics; r.m.s. leakage impedance drop; rectifier transformer; six phase rectifier; tensorial study; theoretical results; voltage matrices;
  • fLanguage
    English
  • Journal_Title
    India, IEE-IERE Proceedings -
  • Publisher
    iet
  • ISSN
    0018-9146
  • Type

    jour

  • DOI
    10.1049/iipi.1974.0014
  • Filename