• DocumentCode
    1453382
  • Title

    Gaseous insulation for high-voltage transformers

  • Author

    Camilli, G. ; Gordon, G. S. ; Plump, R. E.

  • Author_Institution
    General Electric Company, Pittsfield, Mass.
  • Volume
    71
  • Issue
    6
  • fYear
    1952
  • fDate
    6/1/1952 12:00:00 AM
  • Firstpage
    513
  • Lastpage
    513
  • Abstract
    SULFUR HEXAFLUORIDE in high-voltage apparatus fulfills these requirements of a gaseous dielectric: 1. dielectric strength should be high at a low-gauge pressure; 2. temperature of condensation should be equal to or lower than that at which the apparatus is operated; 3. the gas itself and its products of decomposition should not be toxic or of readily controllable toxicity. Similarly, the gas should not corrode materials of construction; 4. the gas should be chemically inert and thermally stable; 5. it should have a high heat transfer coefficient.
  • Keywords
    Dielectric breakdown; Heat transfer; Oil insulation; Power transformer insulation; Sulfur hexafluoride; Thermal stability;