DocumentCode
1453916
Title
A voltage stability security assessment method
Author
Schlueter, R.A.
Author_Institution
Dept. of Electr. Eng., Michigan State Univ., East Lansing, MI, USA
Volume
13
Issue
4
fYear
1998
fDate
11/1/1998 12:00:00 AM
Firstpage
1423
Lastpage
1438
Abstract
A voltage stability security assessment method is developed that can identify (i) each region that experiences voltage collapse and (ii) the equipment outages that cause voltage collapse in each of these regions. The method establishes whether the voltage collapse caused by a contingency is due to clogging voltage instability or loss of control voltage instability. The advantages of the method is that it requires little computation and is comprehensive in attempting to find all regions with voltage collapse problems and all single and double equipment outages that cause voltage collapse in each region
Keywords
power system security; power system stability; clogging voltage instability; double equipment outages; equipment outages identification; loss of control voltage instability; single equipment outages; voltage collapse; voltage collapse region identification; voltage stability security assessment method; Computer networks; Distributed computing; Eigenvalues and eigenfunctions; Load modeling; Reactive power control; Security; Shunt (electrical); Stability; Transmission line discontinuities; Voltage control;
fLanguage
English
Journal_Title
Power Systems, IEEE Transactions on
Publisher
ieee
ISSN
0885-8950
Type
jour
DOI
10.1109/59.736286
Filename
736286
Link To Document