Title :
A low-complexity data-dependent beamformer
Author :
Synnevåg, Johan-Fredrik ; Austeng, Andreas ; Holm, Sverre
Author_Institution :
Dept. of Inf., Univ. of Oslo, Oslo, Norway
fDate :
2/1/2011 12:00:00 AM
Abstract :
The classical problem of choosing apodization functions for a beamformer involves a trade-off between main lobe width and side lobe level, i.e., a trade-off between resolution and contrast. To avoid this trade-off, the application of adaptive beamforming, such as minimum variance beamforming, to medical ultrasound imaging has been suggested. This has been an active topic of research in medical ultrasound imaging in the recent years, and several authors have demonstrated significant improvements in image resolution. However, the improvement comes at a considerable cost. Where the complexity of a conventional beamformer is linear with the number of elements [O(M)], the complexity of a minimum variance beamformer is as high as O(M3). In this paper, we have applied a method based on an idea by Vignon and Burcher which is data-adaptive, but selects the apodization function between several predefined windows, giving linear complexity. In the proposed method, we select an apodization function for each depth along a scan line based on the optimality criterion of the minimum variance beamformer. However, unlike the minimum variance beamformer, which has an infinite solution space, we limit the number of possible outcomes to a set of predefined windows. The complexity of the method is then only P times that of the conventional method, where P is the number of predefined windows. The suggested method gives significant improvement in image resolution at a low cost. The method is robust, can handle coherent targets, and is easy to implement. It may also be used as a classifier because the selected window gives information about the object being imaged. We have applied the method to simulated data of wire targets and a cyst phantom, and to experimental RF data from a heart phantom using P = 4 and P = 12. The results show significant improvement in image resolution compared with delay-and-sum.
Keywords :
array signal processing; biomedical ultrasonics; medical signal processing; phantoms; ultrasonic imaging; apodization function; complexity; data dependent beamformer; heart phantom; image resolution; main lobe width; medical ultrasound imaging; minimum variance beamforming; side lobe level; Array signal processing; Complexity theory; Image resolution; Robustness; Solids; Speckle; Transducers; Algorithms; Models, Biological; Phantoms, Imaging; Signal Processing, Computer-Assisted; Transducers; Ultrasonography;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2011.1805