• DocumentCode
    1453965
  • Title

    Contrast imaging by non-overlapping dual frequency band transmit pulse complexes

  • Author

    Hansen, Rune ; Angelsen, Bjørn A J

  • Author_Institution
    Dept. of Circulation & Med. Imaging, Norwegian Univ. of Sci. & Technol., Trondheim, Norway
  • Volume
    58
  • Issue
    2
  • fYear
    2011
  • fDate
    2/1/2011 12:00:00 AM
  • Firstpage
    290
  • Lastpage
    297
  • Abstract
    SURF contrast imaging, as described previously in the literature, is a contrast agent detection technique achieved by processing of the received signals from transmitted dual frequency band pulse complexes with overlapping high-frequency (HF) and low-frequency (LF) pulses. The transmitted HF pulses are used for image reconstruction, whereas the transmitted LF pulses are used to manipulate the scattering properties of the contrast agent. As with harmonic contrast agent detection techniques, nonlinear wave propagation will, in most situations, also limit the specificity with the SURF contrast technique when transmitting overlapping HF and LF pulses. The present paper proposes an alternative SURF contrast imaging technique using transmit dual frequency band pulse complexes with non-overlapping HF and LF pulses. If the frequency of the LF manipulation pulse is close to the bubble resonance frequency, numerical simulations indicate a significant ring-down effect of the LF bubble radius response. Utilizing this bubble ring-down effect and transmitting the HF pulse just after the LF pulse, a contrast agent specificity approaching infinity accompanied by a contrast agent sensitivity only for contrast bubbles having resonance frequencies within a narrow frequency range may be obtained.
  • Keywords
    biomedical ultrasonics; bubbles; image reconstruction; medical image processing; LF bubble radius response; SURF contrast imaging; dual frequency band transmit pulse complex; image reconstruction; nonlinear wave propagation; nonoverlapping transmit pulse complex; ring down effect; Fluids; Hafnium; Imaging; Mathematical model; Oscillators; Resonant frequency; Scattering; Computer Simulation; Contrast Media; Microbubbles; Nonlinear Dynamics; Signal Processing, Computer-Assisted; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2011.1806
  • Filename
    5716446