DocumentCode :
1455730
Title :
CCE comparison of AC-DC voltage transfer standards at the lowest attainable level of uncertainty
Author :
Klonz, Manfred
Author_Institution :
Phys. Tech. Bundesanstalt, Braunschweig, Germany
Volume :
46
Issue :
2
fYear :
1997
fDate :
4/1/1997 12:00:00 AM
Firstpage :
342
Lastpage :
346
Abstract :
In May 1996 the international comparison of AC-DC voltage transfer standards at the lowest attainable level of uncertainty, which started in Jan. 1994, was completed. A PTB multijunction thermal converter was used as the traveling standard. The results show an agreement of the majority of the participating National Metrology Institutes with the average value of better then 0.5×10-6 at the frequency of 1 kHz, 0.6×10-6 at 20 kHz, 1.4×10-6 at 100 kHz, and 15×10-6 at 1 MHz
Keywords :
measurement errors; measurement standards; voltage measurement; 1 kHz to 1 MHz; AC-DC voltage transfer standards; CCE comparison; National Metrology Institutes; PTB multijunction thermal converter; traveling standard; uncertainty level; Analog-digital conversion; Frequency; Insulation; Laboratories; Measurement standards; Measurement uncertainty; Metrology; Particle measurements; Testing; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.571852
Filename :
571852
Link To Document :