DocumentCode :
1455842
Title :
A method of compensation of the frequency dependent systematic error of the time-division watt-converter
Author :
Jovanovic, Ljubisa D.
Author_Institution :
Inst. Mihajlo Pupin, Beograd, Yugoslavia
Volume :
46
Issue :
2
fYear :
1997
fDate :
4/1/1997 12:00:00 AM
Firstpage :
416
Lastpage :
419
Abstract :
The paper presents a method for the compensation of the frequency dependent systematic error of the Time-Division Multiplier of the Goldberg type (TDM). The method Is based on using the additional correcting circuits on the TDM inputs whereby theoretically perfect compensation can be achieved under conditions derived analytically in this paper. Applying this method it is possible to compensate the systematic error in a relatively large range of input signal frequencies even in the cases when both input signals are not limited to one single frequency but have harmonics. In order to verify the performances of the method an adequate, high precision TDM based watt-converter has been developed. Theoretically and experimentally it is shown that the high performances (accuracy better than ±100×10-6) of the multiplier can be obtained in the input frequency range from 50 Hz to 20 kHz even in the case when the conversion frequency is only 10 times the input signal frequency
Keywords :
error compensation; measurement errors; power measurement; wattmeters; 50 Hz to 20 kHz; compensation; conversion frequency; frequency dependent systematic error; input signal frequencies; time-division watt-converter; Circuits; Distortion; Frequency conversion; Frequency dependence; Frequency measurement; Helium; Power measurement; Time division multiplexing; Voltage; Wattmeters;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.571870
Filename :
571870
Link To Document :
بازگشت